RED Compact 24 Manual de Instruções

Consulte online ou descarregue Manual de Instruções para Aquecedores e fervedores de água RED Compact 24. RED Compact 24 Instruction manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 24
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Instruction manual red-y compact series
compact regulator GCR compact all-in GCA
compact meter GSM & compact switch GCS
Vögtlin Instruments AG – flow technology
Langenhagstrasse 1 | 4147 Aesch (Switzerland)
Phone +41 (0)61 756 63 00 | Fax +41 (0)61 756 63 01
www.voegtlin.com | [email protected]
Vista de página 0
1 2 3 4 5 6 ... 23 24

Resumo do Conteúdo

Página 1

Instruction manual red-y compact seriescompact regulator GCR compact all-in GCAcompact meter GSM & compact switch GCSVögtlin Instruments AG – flow

Página 2 - Design: Michael Huber

Technical InformationPage10Chapter03Vögtlin Manualred-y compact seriesVersioncompact_E4_0Temperature Compensation Thermal mass flow meters measure the

Página 3 - Table of Contents

Mounting & InstallationPage11Chapter04Vögtlin Manualred-y compact seriesMounting & InstallationGeneral Tips Check the packet for external dama

Página 4 - Introduction

Mounting & InstallationPage12Chapter04Vögtlin Manualred-y compact seriesElectrical Connection / Power SupplyWith the battery-operated devices, mou

Página 5

Operation & ServicePage13Chapter05Vögtlin Manualred-y compact seriesOperation & Service Heat-Up Time Right when the device is turned on,red-yi

Página 6 - Mode of Operation

Operation & ServicePage14Chapter05Vögtlin Manualred-y compact seriesVersioncompact_E4_0Battery ReplacementIf ‘low bat’ appears in the display, we

Página 7

Alarm & Switch FunctionPage15Chapter06Vögtlin Manualred-y compact seriesAlarm & Switch Function Individual Functions in Detail Resetting the A

Página 8

Alarm & Switch FunctionPage16Chapter06Vögtlin Manualred-y compact seriesVersioncompact_E4_0 © Vögtlin Instruments AGalsetpAlarm SetpointalfuncAlar

Página 9

Alarm & Switch FunctionPage17Chapter06Vögtlin Manualred-y compact seriesVersioncompact_E4_0Alarm situations Situation 1 / Parameters:Function Valu

Página 10 - Technical Information

TotalizerPage18Chapter07Vögtlin Manualred-y compact seriesVersioncompact_E4_0TotalizerGeneralThe Totalizer function can be activated by the manufactur

Página 11 - Mounting & Installation

DimensionsPage19Chapter08Vögtlin Manualred-y compact series © Vögtlin Instruments AG1443.32525.52543.569(25.5)(12.7)88.6 12.7114ø19343.3258.731.8ø6.8ø

Página 12

Page2Chapter00Vögtlin Manualred-y compact seriesInstruction manual red-y compact seriescompact meter GCMcompact regulator GCRcompact switch GCScompact

Página 13 - Operation & Service

DimensionsPage20Chapter08Vögtlin Manualred-y compact seriesVersioncompact_E4_0Dimensions smart controller G1/2”© Vögtlin Instruments AGAnsicht B / Vie

Página 14

AnnexPage21Chapter09Vögtlin Manualred-y compact seriesAnnexPressure Loss© Vögtlin Instruments AG0900.20.40.60.81.01.21.41.60 100 200 300 400 500Flow m

Página 15 - Alarm & Switch Function

AnnexPage22Chapter09Vögtlin Manualred-y compact seriesVersioncompact_E4_0 © Vögtlin Instruments AGDruckverlust Typ - 200 ln/min02040608010012014016018

Página 16

AnnexPage23Chapter09Vögtlin Manualred-y compact seriesType Code Main function G gasflowSeries C compact seriesFunction M MeterR RegulatorS SwitchA All

Página 17

AnnexPage24Chapter09Vögtlin Manualred-y compact seriesContamination Statement With return of devices, please fill out the following statement complete

Página 18 - Totalizer

Table of ContentsPage3Chapter00Vögtlin Manualred-y compact series01 Introduction 4Operator BenefitsService and QualityGuarantee02 Mode of Operation 6M

Página 19 - Dimensions

IntroductionPage4Chapter01Vögtlin Manualred-y compact seriesWelcomeWith red-yyou get the latest, most modern CMOS sensor technology. CMOSensTMis a tec

Página 20

IntroductionPage5Chapter01Vögtlin Manualred-y compact seriesTips and WarningsBefore putting the instrument into use, these operating instructions shou

Página 21 - Pressure Loss

Mode of OperationPage6Chapter02Vögtlin Manualred-y compact seriesA bit of theory Measuring principleThe measuring principle of thermal flow measuremen

Página 22 - Pressure Loss 200ln/min

Mode of OperationPage7Chapter02Vögtlin Manualred-y compact seriesThe digital intelligence linked with the CMOSensTMsensor permits the emission of a fu

Página 23 - Type Code

Technical InformationPage8Chapter03Vögtlin Manualred-y compact seriesTechnical Information General Specifications of the Device Accuracy+/- 1% of full

Página 24

Technical InformationPage9Chapter03Vögtlin Manualred-y compact seriesMeasurement Ranges Red-ymeasurement and control devices are supplied with standar

Comentários a estes Manuais

Sem comentários