Problems/Causes/Solutions Technical service - Rights reserved - Reproduction prohibited
PROBLEM
LED
POSSIBLE CAUSES Solutions:
The stove is
signalling pellet
hopper temperature
over the safety limit
Led 0.
Pellet load too high
Room fan power too low
Structure has overheated due to
reduced heat dissipation.
Room fan faulty
Wait for the stove to cool,
re-ignite it and decrease the
pellet load following the
instructions in section 4.10
Wait for the stove to cool,
re-ignite it and increase the
fan using knob A
Verify the correct
positioning of the stove
Increase the smoke fan
speed according to the
technical manual
Replace the room fan
The stove signals
anomalous
operation of the
smoke fan
Led +1
Impediment in fan rotation
Smoke fan faulty
Check the reason for the
impediment
Replace the faulty
component
The stove signals
smoke temperature
too high or smoke
probe faulty
Led +2
Pellet load too high
Unsuitable pellets.
Room fan power too low
Structure has overheated due to
reduced heat dissipation.
Room fan faulty
Smoke probe faulty
Smoke outlet blocked
Increase the pellet load
following the instructions in
section 4.10
Remove the unsuitable
pellet from the hopper and
exchange it with one
recommended by the
manufacturer
Increase the fan speed
using knob A
Verify the correct
positioning of the stove
Replace the faulty
component
Clean the smoke outlet
The pellets
accumulate in the
grate
Pellet load too high
Insufficient combustion area.
Pellets damp or unsuitable.
Door open
Smoke outlet blocked
Gaskets worn
Increase the pellet load
following the instructions in
section 4.10
Make sure that the
combustive air inlet in the
back of the stove is free
from obstructions or
blockages
Remove the unsuitable
pellet from the hopper and
exchange it with one
recommended by the
manufacturer
Check that the door is
properly closed
Clean the smoke outlet
Increase the smoke fan
speed according to the
technical manual
Replace the faulty
component